Greetings -

I am in the process of loading a series of Renishaw macro's into my Fanuc 18i-MB. Parameter Write Enable (PWE) is 1; 12010 is 2; 12011 is 8980; 12012 is 12010. I want to change the range of embedded macro's by changing the value in 12011. When I try and change it I get a "WRITE PROTECT" error. I can change 12010 as well as other parameters so the issue doesn't seem to be simple parameter editing.

Is there another level of protection or something else I have missed to change parameters 12011/12012?

Thanks - Jon
 
Look in the parameter book at the description of 12013. That is the parameter for the password for embedded macros. Also parameter 12001 bit 0 disables embedded macro entry and 12010 enables/disables embedded macro referencing and editing.
 








 