Fanuc 11M dead in water

dexta

Aluminum
Joined
Mar 31, 2010
Location
canada
Good Day.

After finally cleaning up our new (old ) Kitamura 3B mill, we booted it up. SYstems came up just fine.. for 10 mins.. after that went dead.. these are the steps that ware taken..I'm wondering if someone has any ideas what to do...?


Systems boots up fine at the beggining.
after 10 mins AL05, thermal overheat.
by accident the secundary breaker has been shut, ( 16A ) next to the main breaker.
after that system cbooted but game be buss comm error CPU#2, with a system dump
removed all cables from the PCB booted.. no sign of life what so ever..
only number one is in the left connect.. no activity on the CRT..
motherboard is A16B-1010-0200, 3 axis systems 11M standard.

thank you for all input..
Peter
 
no that machine came 220/3ph.. from what I checked all was ok ..214VAC on each leg..
now the MB doesn't boot ... retrofit anyone.. ?
 
yes.. crt and other electronics come up.. the mb ( A16b-1010-0200) come up as well .. however only a part of a letter come up sometimes the number 1 appears.. but no activity on the crt.. none.. anyone has a troubleshooting manual for the beast..?
 








 