I don’t have the detail of the Oi options. If you are missing some of them that were previously installed then all you would have to do is get the originals and re-download them.
Pixman is correct. Your best bet is to contact DAEWOO or call Fanuc and give them the serial number of the control and they should have a file of the original parameters for you. If you get lucky most MTB put a hard copy of all the parameters in the power cabinet. Take a peek in there to see if you got them.
You don’t have a backup of the control? Backup, backup, backup. There is nothing worse than spending time and money trying to hunt down the original data for a MT that takes 5mins to do a complete backup of.
Stevo
hello all
sorry for too late replying
i used hard copy i used slot memory card to copy the data (parameter and ladder) in machine memory card , but machine not accept all parameter specially 9900 to 9998 , i tell u before
one more thing i share for u , that my machine back panel pmc module display card are repair . may be electronic guy who repair that card , he open (eject) the sram machine memory , and machine lost parameter some where
machine lost also all programs
PMT u say that u know how to change and display the 9900 paramter in machine plz tell me the details , how all 9900 series display me and also how i change the bit value in 9900 to 9998 series
i think may be some software problem ,if i use machine back up data when machine NC buton is on and before displaying loading in Dram
i have another same oi series machine , can i use that machine back up data for this machine ,
i know the procedure of backup data read in machine but some where hesitancy in me , bcz first time i load a back up data in machine in start when NC on
PMT and Stevo if u know the procedure of back up data loading in start in the machine , then plz tell me .bcz i want to know the procedure line by line .
Any other know the start back up data loading line by line procedure
ANY more suggestions and idea are greatly appreciated
thx
usman