Don't know about the last 2, but the first 3 are correct...
Ss s = The work offset number that will be set.
S1 to S6 (G54 to G59).
S0 (external work offset).
S101 to S148 (G54.1 P1 to G54.1 P48) additional offsets option.
New work offset = active work offset + error.
New external offset = external offset + error.
Example: S3.
Don't forget the . after the S value.
Best way to learn the software is to grab a copy of the inspection plus manual and read it. IT forms the foundation for every cycle. Once you have a handle on that, grab the easyset manual so you don't need a work offset to make a measurement. The manuals are available from the renishaw website I believe. If not you can ask them and they will send you the documents.
Notice
This website or its third-party tools process personal data (e.g. browsing data or IP addresses) and use cookies or other identifiers, which are necessary for its functioning and required to achieve the purposes illustrated in the cookie policy. To learn more, please refer to the cookie policy. In case of sale of your personal information, you may opt out by sending us an email via our Contact Us page. To find out more about the categories of personal information collected and the purposes for which such information will be used, please refer to our privacy policy. You accept the use of cookies or other identifiers by closing or dismissing this notice, by scrolling this page, by clicking a link or button or by continuing to browse otherwise.