FP4A Contour 2 ; Error 38 ; NPP90 Eprom 44205-401.02 und 44907-461.02
Close
Login to Your Account
Results 1 to 2 of 2
  1. #1
    Join Date
    Jan 2011
    Location
    Germany,35764 Sinn
    Posts
    43
    Post Thanks / Like
    Likes (Given)
    11
    Likes (Received)
    4

    Default FP4A Contour 2 ; Error 38 ; NPP90 Eprom 44205-401.02 und 44907-461.02

    Hi, I have a little Problem with an FP4A ; Contour2
    When i start the machine it gives an Error Message on the screen which shows Error 38.
    This belongs to an Software Error on the NPP90.

    44907-461-02-npp90-ic36-a
    44907-461-02-npp90-ic37-b
    -
    -
    44205-401-02-npp90-ic40-e
    44205-401-02-npp90-ic41-f


    I've read out the eprom content and it was the same as i have from another card.
    So I am not sure if this EPROM Data i have is OK.
    Does anybody have this version and can sent it to me please ?

    Also the Machine shows the LED 3,6,7 on the NPP90 which stands for "Error in Communication between PC and CNC".

    Thanks for ideas what also should be checked.

    Regards
    Michael

  2. #2
    Join Date
    Jan 2011
    Location
    Germany,35764 Sinn
    Posts
    43
    Post Thanks / Like
    Likes (Given)
    11
    Likes (Received)
    4

    Default

    It was a bad batterie on the NSV90 card which produced that error.
    Problem solved