AgieCharmilles CUT 20 P Breaking Wire
Close
Login to Your Account
Results 1 to 8 of 8
  1. #1
    Join Date
    Sep 2003
    Location
    Alabama
    Posts
    19
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default AgieCharmilles CUT 20 P Breaking Wire

    As stated this machine suddenly started breaking the wire. It may break as soon as contact is made with the material or it may cut for a couple minutes before breaking. I haven't run this machine much and need some guidance on what to look for.

  2. #2
    Join Date
    Dec 2015
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    41
    Post Thanks / Like
    Likes (Given)
    12
    Likes (Received)
    12

    Default

    I don't run a cut 20 but it sounds like one or more of the following. Wrong power setting, poor flushing,worn contacts, worn power feed cables, or maybe breakage strategies turned off.

  3. #3
    Join Date
    Aug 2010
    Location
    New England
    Posts
    221
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    26

    Default

    what material? How thick? check contacts, change wire, flush working? how close are nozzles? they should be .002-.004 away. why not call GFMS?

  4. #4
    Join Date
    Sep 2017
    Country
    UNITED STATES
    State/Province
    California
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    4

    Default

    The tricky one is a worn lower contact. The controller "checks for spark quality feedback" there.

  5. #5
    Join Date
    Feb 2007
    Location
    Angleton, Texas
    Posts
    1,769
    Post Thanks / Like
    Likes (Given)
    934
    Likes (Received)
    523

    Default

    Had a CUT-400 do that for no apparent reason.

    Turned out to be bad caps in the cutting power supply.

  6. #6
    Join Date
    Aug 2010
    Location
    New England
    Posts
    221
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    26

    Default

    cut 400 cut 20 not the same generator

  7. #7
    Join Date
    Oct 2017
    Country
    ROMANIA
    Posts
    10
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    1

    Default

    try to increase SSol parameter (60-70) and decrease P parameter (15-30), also decrease by 1-2N wire tension - all of this from the tec. optimization

  8. #8
    Join Date
    Aug 2010
    Location
    New England
    Posts
    221
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    26

    Default

    check lower contact wetting. procedure is described in chapter 8 Maintenance section 3.10 also check upper contact wetting section 3.9