Zahnrad Kopf
Diamond
- Joined
- Apr 5, 2010
- Location
- Tropic of Milwaukee
90HA
S01 Servo Error being reported as an error 10 (0010) and in X.
This is an undervoltage error.
Oddly, all incoming voltages are good. Checked numerous times and points.
This would seem to point to an error on the servo drive, but noone seems to know WHAT.
I've seen some talk of it possibly being an opto isolator issue, but not which OI.
Also, I cannot seem to find anything that list what the voltages at the terminals of the servo card should be so that I can test at that point.
MitsTech? Anyone?
S01 Servo Error being reported as an error 10 (0010) and in X.
This is an undervoltage error.
Oddly, all incoming voltages are good. Checked numerous times and points.
This would seem to point to an error on the servo drive, but noone seems to know WHAT.
I've seen some talk of it possibly being an opto isolator issue, but not which OI.
Also, I cannot seem to find anything that list what the voltages at the terminals of the servo card should be so that I can test at that point.
MitsTech? Anyone?