Okuma OSP-200 ALARM 2715 "Wrong T Command" 15

jdgarner13

Plastic
Joined
Nov 7, 2014
When I try to tool change to a designated large diameter tool I get an alarm 2715, Wrong T command, 15. The alarm description page explains that the tool pot cannot accept large diameter tools. We have ran this same tool in the same pot for a very long time. This issue just started. The tool\pot data page shows that the pot in question is noted as a large diameter and heavy tool. The two pots above and below are both designated as dummy tools. I took the tool out of the magazine and changed the designation and the atc worked fine. I cannot figure out what the cause nor the solution is. Can anyone offer some advice?
 
I was able to figure out the issue. The magazine was full and didn't have a place for the tool.
 
Yeah, that'll certainly cause an issue.

Good that you figured it out.
 








 