- Location
- Columbia Missouri
I am assembling a temporary 5 hp RPC for use on a 5 hp shaper I am cleaning up. I will not be running it under load- but do need to run it to work on the oil circulation system, etc.
I have several Sq D 30 amp class 8903 type smg 3 series A lighting contactors.
http://stevenengineering.com/tech_support/PDFs/45NLTCO.pdf
indicates
"Motor Loads. These loads consist of motors having an inrush current,
or locked-rotor current, of approximately six times the
full-load current. Square D Type S lighting contactors
are fully rated for motor loads and have a horsepower
rating equal to the equivalent NEMA-Size motor
contactor."
30 AMP would be a NEMA size one - and 7.5 hp on 3 p 208-230V
For a tungsten load it indicates:
Type SM 30 Amperes
When Connected 1 Pole to Load ---------------277 Vac
When Connected 2 Poles to Load on 1PH and
3 Poles to Load on 3PH--------480 Vac
Another table on mixed motor/non-motor loads indicates the max single phase hp is 3 hp.
I assume this is per pole- and that if I use two of the poles for the single phase input to the RPC I will be OK- as the tungsten information suggests.
Can some one confirm this?
I have several Sq D 30 amp class 8903 type smg 3 series A lighting contactors.