Just picked up this bandsaw. I think I have this figured out but would like second opinions from those with more experience.
1: the motor is a 2 HP, 2.9 amps at 460/5.8 at 230, 3 phase. I have already reconfigured the wiring to 230v.
2: it has an external transformer with a 120 outlet attached for the light. Picture. I reconfigured the “H” side from 460 to 230. The “X” side was already configured to 120 so I left it as is.
3. Looks like an internal transformer in the box. See pictures. Haven’t done anything here. I assume just need to reconfigure as the diagram shows?
4: the thermal fuses? It currently has E37 and I’m thinking I need E47 with the 5.8v at 230.
The saw also has a welder that I’m not dealing with for now but will probably have some questions later.
Any help confirming or correcting me is greatly appreciated!
Thanks
Bob
1: the motor is a 2 HP, 2.9 amps at 460/5.8 at 230, 3 phase. I have already reconfigured the wiring to 230v.
2: it has an external transformer with a 120 outlet attached for the light. Picture. I reconfigured the “H” side from 460 to 230. The “X” side was already configured to 120 so I left it as is.
3. Looks like an internal transformer in the box. See pictures. Haven’t done anything here. I assume just need to reconfigure as the diagram shows?
4: the thermal fuses? It currently has E37 and I’m thinking I need E47 with the 5.8v at 230.
The saw also has a welder that I’m not dealing with for now but will probably have some questions later.
Any help confirming or correcting me is greatly appreciated!
Thanks
Bob