hi Guys,

I need some help programming the Allen Bradley 1336S brf50 VFD to run a unimac washer. It had the same unit on the washer which is now not usable. I bought a new Inverter and now wish to program it to run with this washer. I know the input parameter should be 12. i have managed to program the input parameter. But it does not recognize the inputs. What are the other things i need to program into the unit. Can someone please help me out. I have just programmed the input parameter.

Thanks a lot.
 
I'll post a diagram for 'ya tomorrow...

But for now:

Default all parameters.
Input Mode = 12
Frequency Reference = REMOTE POT
Direction Mask = 111111111

Connect L4 pin 24 to 25.
Connect L4 pin 29 to 30.

L4 pin 19 is FWD (short to Common for FWD)
L4 pin 20 is ESTOP (short to Common to RUN)
L4 pin 21 is Common
L4 pin 22 is REV (Short to Common for REV)

Give that a shot, I'll bet it spins!
 








 