Hello- I am having trouble with programming this VFD. It is on a Laguna wood bandsaw. 5hp, 3600 rpm motor.
Max Hz was set to 60. I want to go 90Hz. I downloaded the manual, and I am having a heck of a time.
Initially, when I hit Start, it goes to 90Hz, but if you move the speed pot, it errors out, saying current too high.
I have programed maybe 30 or more VFDs in my time, but this one is not cooperating.
What I tried...
F00 Data protect off = 0
F03 Max Freq = 90 (was 60)
F04 Base Freq = 60 (90 did not work)
F07 Accel Time = 5 sec
F08 Decel Time = 5 sec
F15 Freq Limiter High = 100 (was 70)
All other values are default.
All programed motor data is from the nameplate.
Only thing I have not played with is Current Limiting F43.
Other Q's, How can I do Free Run Stop?
I would call tech support, but it is INDIA, Uggh!
Could anyone familiar with this VFD help me?
Link to the manual:
http://www.geindustrial.com/publibrary/checkout/Installation%20and%20Instruction|GEH-6647|PDF
Thanks-