Results 1 to 4 of 4
  1. #1
    dexta is offline Plastic
    Join Date
    Mar 2010
    Location
    canada
    Posts
    11

    Default wsc-6 thread, aot / man mode question

    good Day gents
    just a quick one.. any suggestion on the code to be used for successfull threading? G92 or G76 ? getting p/S 10 /7 on both of them , another question I have is that when switching from setup to auto.. going back to setup is getting more and more difficult.. sometime it goes in but most of the times have to e-stop and restart the machine. Any suggestion on what conditions have to be set to be abe to freely switch from auto / setup?

    regards
    Peter
    Dexta

  2. #2
    Mark McGrath is online now Titanium
    Join Date
    Mar 2002
    Location
    Scotland
    Posts
    3,942

    Default Canned cycle

    I`m hoping you meant OT-A control.
    If so,it`s G76 and it`s two lines.If you have problems send me your email and I`ll scan a couple of pages for you.

    On your Auto/setup problem we initially thought the programme had not finished running and was waiting on something but when you say it is getting harder and harder our thoughts are on a dodgy button as they are membrane switches and do go eventually.
    You would need to go into the diagnostics to check this.

  3. #3
    dexta is offline Plastic
    Join Date
    Mar 2010
    Location
    canada
    Posts
    11

    Default

    Hello Marc
    Nice to see you're still around. Yes the button sometime goes in sometimes not. Is the setup mode allowed to be switched once the end program LED is on? If it's not too much trouble,please post a sample of sample treading code. Would be greatly appreciated.


    Cheers
    Peter
    infoatdextacadotcom

    Quote Originally Posted by Mark McGrath View Post
    I`m hoping you meant OT-A control.
    If so,it`s G76 and it`s two lines.If you have problems send me your email and I`ll scan a couple of pages for you.

    On your Auto/setup problem we initially thought the programme had not finished running and was waiting on something but when you say it is getting harder and harder our thoughts are on a dodgy button as they are membrane switches and do go eventually.
    You would need to go into the diagnostics to check this.

  4. #4
    Mark McGrath is online now Titanium
    Join Date
    Mar 2002
    Location
    Scotland
    Posts
    3,942

    Default

    Will scan it and email it tomorrow.Please let me know you receive it ok.