What's new
What's new

'Air Pressure Low' - Interact 308 TNC2500B

Steps

Plastic
Joined
Mar 13, 2019
Hi,

I've just started getting 'Air Pressure Low' warning when pressing Tool Unclamp or running M6 tool change on a working machine.

Manual tool change functions as expected and I can swap tools. M6 won't run through of course. Air pressure reads normal at 80psi at machine regulator. Pressure switch functions and closes at 40psi. 24v supply okay.

I've tried looping through the pressure switch (in case air pressure drops during tool change) to maintain 24v signal and traced through to X27 input - still get error message. Tool Clamped/Unclamped microswitches and signals traced through to X22, all okay.

What am I missing?

Thanks.
 
As I'm bypassing the pressure switch, I'm wondering how the control still considers the air pressure to be low. Is there a timing parameter that works in conjunction with the tool clamp microswitches?
 








 
Back
Top