Alarm EX1070
Close
Login to Your Account
Likes Likes:  0
Results 1 to 5 of 5

Thread: Alarm EX1070

  1. #1
    Join Date
    Apr 2021
    Country
    MEXICO
    Posts
    3
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default Alarm EX1070

    Good afternoon everyone, i need your help, i have a chevalier EM2040L with control FANUC SERIES OI-MF and today it showed an alarm EX1070, spindle oil pressure low error, do you know how to fix it? Oil level is full, pressure 15.

    Thanks in advance

  2. #2
    Join Date
    Jun 2018
    Country
    UNITED STATES
    State/Province
    Wisconsin
    Posts
    102
    Post Thanks / Like
    Likes (Given)
    7
    Likes (Received)
    49

    Default

    EX1070 is programmed by the machine tool builder, so Chevalier are the only ones who know exactly what triggers the alarm. Most likely there is a pressure sensor that isn't signaling the oil level is good.

    Forget about what you can see, what can the machine see? Is there a cable cut somewhere, a dead relay in the cabinet, power supply voltage a touch too low? You need to crack open your manuals to A) see if there is a description of the alarm to tell you where to look and B) see what sensors could be triggering the alarm.