    Is there a handy way to calculate this? Say I have a 100 gallon tank that is 20 gallons low and has a 12% concentration. At what concentration do I mix the 20 gallons I'm adding to get it the 100 gallon tank back to 8%? Or a 30 gallon tank at 6% that is five gallons low, at what concentration should I mix the 5 gallons to get it up to 8% ? Sure would be nice to have a chart, or formula, but there's a lot of variables. We just kind of estimate, but I would like to be more precise. We have 10 different size tanks we are trying to regulate, trying to maintain 8% for all. What method do you use?

  2. #2
    Join Date
    Apr 2006
    Location
    Denmark
    Posts
    407
    Post Thanks / Like
    Likes (Given)
    767
    Likes (Received)
    74

    Default

    An interesting problem in elementary mathematics.
    No doubt somebody will jump in before I manage to pull my thoughts in order at this late hour (2230). Will follow this thread and if no proper answers, I will give it a try.
    Hope you're not running out of coolant in the meantime!
    Regards, fusker

  3. #3
    Join Date
    Sep 2007
    Country
    UNITED STATES
    State/Province
    Washington
    Posts
    4,609
    Post Thanks / Like
    Likes (Given)
    93
    Likes (Received)
    1129

    Default

    Quote Originally Posted by RJT View Post
    What method do you use?
    If it's too lean, I add 20% mix.
    If it's too strong (usually the case due to evaporation) I add straight water.

    The formula you would use depends on several factors, which makes the formula a bit cumbersome, but OK ...

    Vi = How many gallons the tank currently has
    Vf = How many gallons you want in the tank after adding mix
    Ri = Current concentration
    Rf = Target concentration
    Radd = Ratio of mix to add to the tank
    Vadd = volume of mix to add in gallons

    Vadd = Vf - Vi
    Radd = (Vf*Rf) - (Vi*Ri) / Vadd

    (I think ...)

    Regards

    Mike

  4. #4
    Join Date
    Feb 2005
    Location
    Hatch, NM Chile capital of the WORLD
    Posts
    8,537
    Post Thanks / Like
    Likes (Given)
    12048
    Likes (Received)
    9674

    Default

    I think the hard part is knowing exactly the volume of MIXED coolant you need to add to get
    the tank full..

    If you want to make it simple.. Its

    The Amount of Concentrate in a FULL TANK

    minus

    The Amount of Concentrate IN the tank

    equals the amount to put in..

    You WANT 100 gallons at 8%, 8 gallons of concentrate in the tank.

    You have 80 gallons at 12%.. 9.6 gallons of concentrate.

    You need to add 20 gallons with NEGATIVE 1.6 gallons of concentrate.

    2nd example.

    30 gallons at 8% is 2.4 gallons of concentrate

    You have 25 gallons at 6%. 1.5 gallons of concentrate.

    You need to add 0.9 gallons of concentrate when you top it up..
    That's a MUDDY mix.


    In the first example, you can't make a concentration that is negative, unless you have
    DARK coolant... Though if DARK coolant touches regular coolant, it turns to pure energy
    and we all die.

    Second Example. .9gallons divided by 5 gallons equals 18% mix.

  5. Likes hobbyman, HuFlungDung, atex57, BSCustoms, NeilJ liked this post
  6. #5
    Join Date
    Oct 2011
    Country
    CANADA
    State/Province
    British Columbia
    Posts
    575
    Post Thanks / Like
    Likes (Given)
    14
    Likes (Received)
    351

    Default

    Quote Originally Posted by Bobw View Post

    In the first example, you can't make a concentration that is negative, unless you have
    DARK coolant... Though if DARK coolant touches regular coolant, it turns to pure energy
    and we all die.
    And that is why I never miss a day checking this forum. Thanks I tip my hat.

  7. Likes Bogart999 9, fusker liked this post
  8. #6
    Join Date
    Sep 2005
    Location
    Oakland, CA
    Posts
    2,069
    Post Thanks / Like
    Likes (Given)
    104
    Likes (Received)
    501

    Default

    Adding straight water to correct too high a concentration is asking for coolant problems as it destroys the water/oil emulsion. Better to add a 1 or 2% solution and work that toward your goal than adding just water. If ya RTFM, it usually tells you this. Just sayin.

  9. Likes fusker, Kaszub liked this post
  10. #7
    Join Date
    Feb 2017
    Country
    UNITED STATES
    State/Province
    Pennsylvania
    Posts
    32
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    10

    Default

    We've been having plenty of trouble with our coolant and pretty sure it is down to us managing concentrations poorly so we've been trying to think of a way to manage this better. I am interested to see how others manage.
    As shown above it's relatively easy calculate how much coolant needs to be added if you know your volumes. Knowing the volume needed to get back to full on different machines is the tricky part in my book.

    What i'm planning on doing is picking an appropriate point on the gauge/tank of each machine and marking this as your refill point.
    Then, using the 5 gallon bucket, figure out how many buckets it takes to get you back to full.
    Now you know the volume you are adding and its the same every time.
    Perform some math wizardry as shown above and print yourself off a pretty chart for each machine with current % and how much coolant to add to the fixed no. of buckets.

    Works in my head anyways but have yet to implement.

  11. #8
    Join Date
    Feb 2009
    Location
    Midwestern MN/Wi USA
    Posts
    1,258
    Post Thanks / Like
    Likes (Given)
    70
    Likes (Received)
    332

    Default

    Dump some water in it and leave few inches for coolant concentration....mixture be damned but the question is as well

  12. #9
    Join Date
    May 2004
    Location
    Paradise, Ca
    Posts
    2,134
    Post Thanks / Like
    Likes (Given)
    621
    Likes (Received)
    1069

    Default

    Quote Originally Posted by Dan from Oakland View Post
    Adding straight water to correct too high a concentration is asking for coolant problems as it destroys the water/oil emulsion. Better to add a 1 or 2% solution and work that toward your goal than adding just water. If ya RTFM, it usually tells you this. Just sayin.
    Unless you're running Oemeta Hycut. Straight water is ok with that coolant.

    I find my guys are surprisingly accurate just guessing. One of them will test the additive and oil concentration first thing in the morning, then add whatever mix he thinks he needs after the machines are up and running. We are never more than 1/2% off. Don't over think this.

  13. Likes steve-l liked this post
  14. #10
    Join Date
    Jan 2005
    Country
    CANADA
    State/Province
    Saskatchewan
    Posts
    9,609
    Post Thanks / Like
    Likes (Given)
    1188
    Likes (Received)
    3293

    Default

    Quote Originally Posted by Bobw View Post
    I think the hard part is knowing exactly the volume of MIXED coolant you need to add to get
    the tank full..

    If you want to make it simple.. Its

    The Amount of Concentrate in a FULL TANK

    minus

    The Amount of Concentrate IN the tank

    equals the amount to put in..

    You WANT 100 gallons at 8%, 8 gallons of concentrate in the tank.

    You have 80 gallons at 12%.. 9.6 gallons of concentrate.

    You need to add 20 gallons with NEGATIVE 1.6 gallons of concentrate.

    2nd example.

    30 gallons at 8% is 2.4 gallons of concentrate

    You have 25 gallons at 6%. 1.5 gallons of concentrate.

    You need to add 0.9 gallons of concentrate when you top it up..
    That's a MUDDY mix.


    In the first example, you can't make a concentration that is negative, unless you have
    DARK coolant... Though if DARK coolant touches regular coolant, it turns to pure energy
    and we all die.

    Second Example. .9gallons divided by 5 gallons equals 18% mix.
    I hope you're correct, that makes more sense than trying to derive the equation I can never remember

  15. #11
    Join Date
    Oct 2013
    Location
    New Jersey
    Posts
    862
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    744

    Default

    I think the important question is do you have a refractometer so you can test how the concentration is changing from evaporation and carryout on parts?

  16. Likes TDegenhart liked this post
  17. #12
    Join Date
    Mar 2004
    Location
    Waukesha, WI
    Posts
    7,504
    Post Thanks / Like
    Likes (Given)
    702
    Likes (Received)
    1817

    Default

    I don't put that much worry into it. I check with the refract, and if it's too high, I mix some water with just a splash of coolant, to bring it down. Pour it in, run it and see where it went from there. If you want to run at 8%, don't fret too much if it winds up at 9 or 7. Much more important things to worry about.

  18. Likes fusker liked this post
  19. #13
    Join Date
    Oct 2014
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    88
    Post Thanks / Like
    Likes (Given)
    366
    Likes (Received)
    16

  20. Likes fusker liked this post
  21. #14
    Join Date
    Aug 2006
    Location
    greensboro,northcarolina
    Posts
    2,145
    Post Thanks / Like
    Likes (Given)
    108
    Likes (Received)
    400

    Default

    I agree, knowing how many gallons it will take to fill the tank is an estimate. Some machines get used daily, others may sit for a week idle. Everyone mixing their own will ad more variables, maybe one guy should do it all the time for more consistency, but to really get a handle on it,looks like it should be done daily with each machine. How often do you check / add coolant?

  22. #15
    Join Date
    May 2004
    Location
    Paradise, Ca
    Posts
    2,134
    Post Thanks / Like
    Likes (Given)
    621
    Likes (Received)
    1069

    Default

    Quote Originally Posted by RJT View Post
    I agree, knowing how many gallons it will take to fill the tank is an estimate. Some machines get used daily, others may sit for a week idle. Everyone mixing their own will ad more variables, maybe one guy should do it all the time for more consistency, but to really get a handle on it,looks like it should be done daily with each machine. How often do you check / add coolant?
    We check / add every morning as part of starting up the shop, no exceptions.

  23. #16
    Join Date
    Apr 2006
    Location
    Denmark
    Posts
    407
    Post Thanks / Like
    Likes (Given)
    767
    Likes (Received)
    74

    Default

    Quote Originally Posted by [email protected] View Post
    Don't over think this.
    Quite right. It took me a few hours to construct the equations and nobody would pay me for time and effort. Quite funny, though. I felt quite clever, long as it lasted.

    fusker

  24. Likes DrHook, Mr.Anderson liked this post
  25. #17
    Join Date
    Oct 2014
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    88
    Post Thanks / Like
    Likes (Given)
    366
    Likes (Received)
    16

    Default

    TRIM/Master Chemical has an Excel sheet Downloadable Document

  26. #18
    Join Date
    Aug 2006
    Location
    greensboro,northcarolina
    Posts
    2,145
    Post Thanks / Like
    Likes (Given)
    108
    Likes (Received)
    400

    Default

    Mike,
    Using your calculations, what happens when you come up with negative number?

    Vi = How many gallons the tank currently has 85
    Vf = How many gallons you want in the tank after adding mix 100
    Ri = Current concentration 10
    Rf = Target concentration 8
    Radd = Ratio of mix to add to the tank
    Vadd = volume of mix to add in gallons 15

    Vadd = Vf - Vi =15
    Radd = (Vf*Rf) - (Vi*Ri) / Vadd Radd = (100 x 8) - (85 x 10) / 15 = -3.33


    Mix at 3.33 % ??

  27. #19
    Join Date
    Nov 2013
    Country
    UNITED STATES
    State/Province
    Utah
    Posts
    2,563
    Post Thanks / Like
    Likes (Given)
    708
    Likes (Received)
    1366

    Default

    You guys need Hobbies, try Curling.

    R

  28. #20
    Join Date
    Jan 2008
    Location
    Cary, NC
    Posts
    105
    Post Thanks / Like
    Likes (Given)
    39
    Likes (Received)
    19

    Default

    Mike,

    The only way to get negative concentration to add is if the amount of coolant in the water is already more than should ever get in the full tank.

    If that happens, it means you added too much coolant at some earlier time. Flush some amount of the mix, recalculate, repeat as necessary until you get a non negative ratio.


Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •