Darren Janecky
Plastic
- Joined
- Jul 20, 2018
Hi, our machine is a 2008 VMC6030 HT with a Fanuc 18i control. I'm looking for a second opinion. On Ref Return at start-up, I get a 445 n-axis: Soft Disconnect Alarm. I say "n-axis", as it occurs on all X,Y, and Z axis at random, perhaps slightly favoring the Y-axis. This happens on Cold Start. We had a Service call, but they wouldn't touch the Fanuc side, and I had a call in to Fanuc, who suggested Servo Amp replacement. This is a single "drive" machine, so unfortunately swapping axis is not possible. The Servo Amp is quite expensive, and I can find very little information on this. There's another thread I think here from 2012 that had a similar problem that an Amp swap did NOT fix. I would like to avoid that of course. As the Fanuc Tech said, it would be extremely unlikely for this to be a cabling/encoder issue on all 3 axis, correct? My gut said it's the drive as soon as it started happening, but fresh opinions are helpful. Anyone ever see this before?
Thanks,
Darren
Thanks,