Gents,
I have a Johnford SV-40 with a fanuc 16 control. it will not accept the following:
M98P1001
G00 X1.625 Y0.0
M98 P1001.
It goes back to the original position and repeats the sub routine. It will however take this:
M98P1001
G00 G55
M98P1001.
IN both instances G54 was the original work offset. do I need to change a paramater? If so any clue to which one?
Thank you all
Fred T
I have a Johnford SV-40 with a fanuc 16 control. it will not accept the following:
M98P1001
G00 X1.625 Y0.0
M98 P1001.
It goes back to the original position and repeats the sub routine. It will however take this:
M98P1001
G00 G55
M98P1001.
IN both instances G54 was the original work offset. do I need to change a paramater? If so any clue to which one?
Thank you all
Fred T