Help Nakamura Tome WT-150 A160 disconnection Alarm

Ch@rles1982

Plastic
Joined
Jun 13, 2019
Operation Message Upper

A160 Disconnection of 1st spindle
**** Details ****
alarm related to disconnection of SP (spindle) power line occurred
in the 1st spindle. the power line of the 1st SP may be broken. the
machine stops in the emergency stop mode during the alarm. check if
there is any problem in the SP power line. this alarm may also issued
by overload of machine or belt tension.


* i was running the machine at low feed after writing a program to make sure i dont crash the
machine then that alarm came up.

has anybody figured out a way to fix this alarm or has anybody have any idea on how to fix it?
please help,,, thanks in advance
 
As a fellow WT-150 operator first thing I'd check is the connections to the motor. Check the screw terminals under the cover on the terminal block (black plastic box) on the motor. Next, check the terminals on the amplifier modules in the cabinet. It should be the 2nd and 3rd amplifier left to right. With the power off, break them loose and re-tighten them. Power up and see if that cures it.
 








 