    Default Hitachi Seiki HT20S III Will not cycle start. "SYSTEM NO. 1!" alarm

    My Hitachi Seiki HT20 III with Seicos LY control had several problems . After repairing a burnt trace on the Hitachi Seiki board with all the relays and connectors I was able to get the machine to come ready. I replaced a relay and was able to get the chuck to clamp and unclamp. I can move, home X and Y, I can jog the spindle and index the turret. The tail stock moves but when I try to give MDI command I get the same alarm and I looked everywhere but don't know what it means " SYSTEM NO. 1!" flashes on the screen that is all it says. Does anyone have any idea what is causing this alarm? I have all the books to the machine but Im puzzeled.

  2. #2
    Join Date
    Feb 2013
    Location
    CT, USA
    Posts
    80
    Post Thanks / Like
    Likes (Given)
    7
    Likes (Received)
    10

    Default

    Quote Originally Posted by Priemum Machine View Post
    My Hitachi Seiki HT20 III with Seicos LY control had several problems . After repairing a burnt trace on the Hitachi Seiki board with all the relays and connectors I was able to get the machine to come ready. I replaced a relay and was able to get the chuck to clamp and unclamp. I can move, home X and Y, I can jog the spindle and index the turret. The tail stock moves but when I try to give MDI command I get the same alarm and I looked everywhere but don't know what it means " SYSTEM NO. 1!" flashes on the screen that is all it says. Does anyone have any idea what is causing this alarm? I have all the books to the machine but Im puzzeled.


    Hello

    Under your SET Menu, you probably have parameter write enable turned on - take a look. Turn it off and you should be good

    John

  3. Likes roysol liked this post
  4. #3
    Join Date
    Dec 2017
    Country
    UNITED STATES
    State/Province
    Texas
    Posts
    3
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    2

    Default As soon as I read your message I smacked myself in the head.

    Quote Originally Posted by shas595 View Post
    Hello

    Under your SET Menu, you probably have parameter write enable turned on - take a look. Turn it off and you should be good

    John
    I never enabled PWE and the whole "SYSTEM NO.1!" alarm was throwing me for a loop. Changed it now everything is working. Thanks a lot!

  5. Likes shas595, roysol liked this post
  6. #4
    Join Date
    Feb 2013
    Location
    CT, USA
    Posts
    80
    Post Thanks / Like
    Likes (Given)
    7
    Likes (Received)
    10

    Default

    Glad it worked out for you! If you need anything else just let me know!

    John

    Quote Originally Posted by Priemum Machine View Post
    I never enabled PWE and the whole "SYSTEM NO.1!" alarm was throwing me for a loop. Changed it now everything is working. Thanks a lot!


Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
2