What's new
What's new

Long Dwell times while probing

RAPID100

Plastic
Joined
Mar 5, 2021
Location
Oldsmar
hey so ive programmed a part with 2 operations. the first op probe time is very normal picking up my X and Y for G54. for my second op im calling an external program with M98 and probing in G55. this is where i notice longer dwell times with the probe. this happens in every linear motion it makes. Professor google dosent have a lot to say on this issue. has anyone ever experienced something along these lines? btw im using a renishaw OMP40-2 on a VF-4 and programming with fusion.
 
Are you inadvertently using dprint? Like using renishaw reporting for some reason? Just for kicks you could up your rs232 baud and see what that does. For some reason I notice this on haas/renishaw bore measurement cycles.
 
This happened on my VF-2SS. My HFO said I had somehow corrupted a file. They had a procedure for fixing it but I had them come out and fix it. The machine would pause every time I hit cycle start while probing.

Good luck

Ron
 








 
Back
Top