So had a problem last night with our ancient ST40.
When it powers up it comes up with multiple alarms.
T32-2 control.

202 HYDRAULIC PRESSURE DOWN (RED)
203 AIR PRESSURE DOWN (RED)
303 START COND. ERR,(EXT FEED HOLD) (BLUE)
121 OVERTRAVEL (RED)

On the control panel I have an NC alarm and MC Alarm
The MC alarm comes on first.

Inside the cabinet I have E7 Alarms

Of course there is a rush job on this machine and I can't contact Mazak till Monday.
Anyone give me an idea to where I should start looking?

Cheers
 
I'm not familiar with that machine or control but I would guess all of those alarms could be caused by an overtravel condition....did the x axis maybe drift down or is it possible any of them have tripped a limit switch? If not maybe a bad limit switch. That is where I would start looking till someone with more knowledge than me reply's.
 
Hi,
The overtravel is a strange one as the machine was parked in it's usual place.
The hydraulics don't fire up in the alarm condition but I will try and manually turn the X Axis leadscrew see if I can get it to move.
I've a feeling all these alarms are caused by some other underlying fault.
 
Check the parameters and see if you have anything funny going on like a bunch of asterisks *** in there. The only time I ever see hydraulic pump not turn on is when the parameters get corrupted due to a low battery.
 
Parameters all seem fine.
Breakers that drive the hydraulics etc are not pulling in.
Just waiting for Mazak to call for when they can get an engineer out.
 








 
Back