We're getting a "304 INVALID I,J OR K IN G02 OR G03" when running a facing operation, at these lines:
N235 G18 G2 X-0.3246 Z-0.0197 I0.0787 K0.
N240 G17 G3 X-0.2858 Y-0.0318 I0. J0.0394
Here's the probe angle cycle.
We thought the issue was with closing with a G69, which worked for a drill test, by inserting it at the end of the program. However the same placement results in an error for a different operation.
(Probe WCS2)
N25 T30 M6
(Stock Haas Probe)
N30 G54
N35 G0 X3.4882 Y2.3524
N40 G43 Z6.1024 H30
N45 T6
N50 G65 P9832
N55 G65 P9810 Z0.1969 F39.37
N60 G65 P9810 Z-0.3208
N65 G65 P9814 D1.063 Q0.3937
N70 G54
N75 G65 P9814 D1.063
N80 #100=#185
N85 #101=#186
N90 G65 P9810 Z0.1969
N95 G0 Z6.1024
N100 G65 P9833
(Probe WCS2 2)
N105 G1 X17.8504 Y2.3524 F500.
N110 G65 P9832
N115 G0 Z6.1024
N120 G65 P9810 Z0.1969 F39.37
N125 G65 P9810 Z-0.3208
N130 G65 P9814 D1.063 Q0.3937
N135 #102=#185
N140 #103=#186
N145 G53
N150 #189=ATAN[#103-#101]/[#102-#100]
N155 G65 P9810 Z0.1969
N160 G0 Z6.1024
N165 G65 P9833
N170 M5
N175 G53 G0 Z0.
N180 G68 X#100 Y#101 R#189
N235 G18 G2 X-0.3246 Z-0.0197 I0.0787 K0.
N240 G17 G3 X-0.2858 Y-0.0318 I0. J0.0394
Here's the probe angle cycle.
We thought the issue was with closing with a G69, which worked for a drill test, by inserting it at the end of the program. However the same placement results in an error for a different operation.
(Probe WCS2)
N25 T30 M6
(Stock Haas Probe)
N30 G54
N35 G0 X3.4882 Y2.3524
N40 G43 Z6.1024 H30
N45 T6
N50 G65 P9832
N55 G65 P9810 Z0.1969 F39.37
N60 G65 P9810 Z-0.3208
N65 G65 P9814 D1.063 Q0.3937
N70 G54
N75 G65 P9814 D1.063
N80 #100=#185
N85 #101=#186
N90 G65 P9810 Z0.1969
N95 G0 Z6.1024
N100 G65 P9833
(Probe WCS2 2)
N105 G1 X17.8504 Y2.3524 F500.
N110 G65 P9832
N115 G0 Z6.1024
N120 G65 P9810 Z0.1969 F39.37
N125 G65 P9810 Z-0.3208
N130 G65 P9814 D1.063 Q0.3937
N135 #102=#185
N140 #103=#186
N145 G53
N150 #189=ATAN[#103-#101]/[#102-#100]
N155 G65 P9810 Z0.1969
N160 G0 Z6.1024
N165 G65 P9833
N170 M5
N175 G53 G0 Z0.
N180 G68 X#100 Y#101 R#189