hey guys, moved to a new shop that has 240v 3phase not 208 .. changed some of the legs on the transformer in my 2005 romi e320 (fanuc control), to accept the new voltage per Romi. It ran fine for a while.. a month after though looks like the transformer failed, and a tech i spoke to said that the leg on the transformer that had not been used since the machine was new might have been sitting without working for too long causing it to fail when under load.. no sign of anything else.. Thinking of putting a transformer outside the machine for the main power supply.. and going around the internal one, which is really tough to remove where the machine is, and would be costlier by a bunch.. Does anyone have experience doing this? also, where is a good place to look for a transformer for a cnc..
it needs 50KVA 220 to 208 three phase
thank you
Zach
it needs 50KVA 220 to 208 three phase
thank you
Zach