Deckel gk21
Close
Login to Your Account
Likes Likes:  0
Results 1 to 3 of 3

Thread: Deckel gk21

  1. #1
    Join Date
    Jul 2017
    Country
    ALAND ISLANDS
    Posts
    5
    Post Thanks / Like
    Likes (Given)
    3
    Likes (Received)
    0

    Default Deckel gk21

    Hi all,
    I bought a deckel gk21 with a 3 phase 230v dahlander motor. My workshop has 3 phase 400v. What s my best option?
    Thanks
    Simon

    Verstuurd vanaf mijn SM-G930F met Tapatalk

  2. #2
    Join Date
    Jul 2017
    Country
    ALAND ISLANDS
    Posts
    5
    Post Thanks / Like
    Likes (Given)
    3
    Likes (Received)
    0

    Default

    I would kind of like to keep the workshop and the original motor...

    Verstuurd vanaf mijn SM-G930F met Tapatalk

  3. #3
    Join Date
    Nov 2004
    Location
    SLC, UT
    Posts
    673
    Post Thanks / Like
    Likes (Given)
    825
    Likes (Received)
    125

    Default

    You could use a 3 phase transformer or a VFD, many VFDs will let you vary the output voltage via programming parameters in the VFD software.

    The transformer would likely be the best option if you want to "stay factory", as the Deckel pantographs I have observed use some complicated switching of the motor leads to accomplish different speed ranges. If you opt for a VFD, then it would be best practice to bypass the Deckel speed range switching and control the speed of the motor using the VFD.