What's new
What's new

Deckel FP2NC with Dialog 11 Self-test Error

MrEMail

Plastic
Joined
Sep 17, 2021
Hello to all,

I have a problem with a Deckel FP2NC with Dialog 11 control.
The machine I bought used, this stood 7 years unused around. Supposedly it worked perfectly at that time.

I have replaced the batteries in the NSV02 and NSP02 (both were empty). The disk with the machine parameters is available.

The machine did not run through the self test from the beginning:

In the line NSI02 under BPM it shows the error 00C8. Does anyone know this error and what it could mean?

Thanks in advance for any tips on where to look. Component exchange is no problem for me.

Translated with www.DeepL.com/Translator (free version)
 

Attachments

  • Dialog 11 Selbsttest.jpg
    Dialog 11 Selbsttest.jpg
    10.7 KB · Views: 216
The picture is so small I cannot read it.
Tell me both error codes and I will look them up.

Also Germany.

Attached is a better picture.
The SPS error is gone since the batteries are new.

The error code of the NSI is 00C8.
Thanks in advance for the efforts!

IMG_1938.jpg
 








 
Back