G,day Everybody,
The last few days have been very interesting. I,ve set up the Cimco DNC-Max software on my laptop and have nearly cracked the drip feed transfer into the control. It appears to work pretty much the same as the software you have described, Ross. On my laptop I have a file (430kb) I have called 1000. In mode 16 (with the DNC function in mode 15 turned on) From the control I highlight IN press ACKNOWLEDGE and type in 51000 in the highlighted box down the bottom of the screen (the 5 in front of the 1000 asks for the program to be split for transfer to the control) The words NLP aus %51000 appear on the screen and the program begins the transfer. It's split into smaller programs %51001, %51002 %51003............. which appear in Mode 13 with the same words NLP aus %51000 appearing beside that program number. I can run %51000 to the end (line N9999 L 0 %51001) but the machine stops at the end and won't move to %51001. Is there something simple I'm missing, everything else seems to be working perfectly. I,ve had a look at one of your old posts, Ross at the file splitting structure and it appears to be identical as what I have.
Thanks once again everybody, The advice you all give is invaluable
(I would't say the same for the Deckel manual that came with the machine!)
Kind Regards
Brett