This on the Fehlmann P50.... the scales are hidden away within the table so I can't see which scale models it has....but the signal period is currently set at 40um.
The issue is, if I move X to get 1.0000" travel on the DRO, the actual movement is about 1.20". So, seeing as the signal period choices at 10, 20, 40, 100 um seems like changing to one of those would result in more drastic differences. Thoughts ?
The issue is, if I move X to get 1.0000" travel on the DRO, the actual movement is about 1.20". So, seeing as the signal period choices at 10, 20, 40, 100 um seems like changing to one of those would result in more drastic differences. Thoughts ?