tr1gger88
Plastic
- Joined
- Apr 15, 2019
- Location
- Orange County, CA
Hello everyone.
I have a 2009 DMG DMC 1035V machining center (made in Germany) with a Siemens 840D Solutionline control.
The problem I’m having is the machine stopped during a tool change with the tool change arm rotated 90 degrees from home position after having taken tool 1 out of the spindle and putting it back into the tool chain and putting an empty tool position “into” the spindle. Right about the time that the draw bar actuates the machine went into an E-stop alarm and stopped.
I entered the manufacturer password to get to access level 7 and can’t get out of E-stop or enable any of the drives in order to try to do the tool changer recovery process. The drives have 600VDC and 24VDC supplied.
I’m hoping that there may be some PM members that can point me in the direction of working through this. I’m not sure if these errors are pointing to actual hardware failure or if the PLC is not enabling the spindle drive because the tool change arm is in a position that would cause damage if the spindle were to start turning. Any advice would be very much appreciated.
Thanks for your help!
Tyler
Axis SP1 is the spindle.
The alarms are as follows:
25000: Axis SP1 hardware fault of active encoder
25201: Axis SP1 drive fault
201750: Axis SP1 SPI_DW_01 (16):
SI Motion CU:HW fault safety-relevant encoder. 23609.
201711: Axis SP1 SPI_DW_01 (16):
SI Motion CU: Defect in a monitoring channel”. 0.
27113: Axis SP1 hardware encoder error of the safe actual value.
231125: Axis SP1 SPI_DW_01 (16):
Encoder 1: Amplitude error track A or B overcontrolled. A-track: 32769, B-track: 32769
Messages:
700360: EMERGENCY STOP actuated or switch on control voltage by actuating illuminated pushbutton
600314: Feed interlocking-Z: Changer arm not in home position
701204: Exp_V_Interlocking: Main axes in Hopper area -> Relieve axes is necessary
System info:
PLC-No.: 4B0000_SCGR_01E
NCU 710
PCU50
NC-Software : NCK_01.05_00.04
PLC-Software : 4B0000_SCGR_01E
I have a 2009 DMG DMC 1035V machining center (made in Germany) with a Siemens 840D Solutionline control.
The problem I’m having is the machine stopped during a tool change with the tool change arm rotated 90 degrees from home position after having taken tool 1 out of the spindle and putting it back into the tool chain and putting an empty tool position “into” the spindle. Right about the time that the draw bar actuates the machine went into an E-stop alarm and stopped.
I entered the manufacturer password to get to access level 7 and can’t get out of E-stop or enable any of the drives in order to try to do the tool changer recovery process. The drives have 600VDC and 24VDC supplied.
I’m hoping that there may be some PM members that can point me in the direction of working through this. I’m not sure if these errors are pointing to actual hardware failure or if the PLC is not enabling the spindle drive because the tool change arm is in a position that would cause damage if the spindle were to start turning. Any advice would be very much appreciated.
Thanks for your help!
Tyler
Axis SP1 is the spindle.
The alarms are as follows:
25000: Axis SP1 hardware fault of active encoder
25201: Axis SP1 drive fault
201750: Axis SP1 SPI_DW_01 (16):
SI Motion CU:HW fault safety-relevant encoder. 23609.
201711: Axis SP1 SPI_DW_01 (16):
SI Motion CU: Defect in a monitoring channel”. 0.
27113: Axis SP1 hardware encoder error of the safe actual value.
231125: Axis SP1 SPI_DW_01 (16):
Encoder 1: Amplitude error track A or B overcontrolled. A-track: 32769, B-track: 32769
Messages:
700360: EMERGENCY STOP actuated or switch on control voltage by actuating illuminated pushbutton
600314: Feed interlocking-Z: Changer arm not in home position
701204: Exp_V_Interlocking: Main axes in Hopper area -> Relieve axes is necessary
System info:
PLC-No.: 4B0000_SCGR_01E
NCU 710
PCU50
NC-Software : NCK_01.05_00.04
PLC-Software : 4B0000_SCGR_01E