What's new
What's new

actspark sp100

ZIMMYB

Plastic
Joined
Jul 12, 2020
Hi
I have recently purchased a actspark sp3 and have powered it up.(sp100 generator)However when i go to return the axis to home (x,y and z)it alarms our with a SYNCHRONIZATION FAIL WITH GENERATOR ALARM E003.
Any help with this would be much appreciated.
Kind regards
Paul Reid
 
can you move the machine with the hand pendant?
This error refers to SDC-30 board (axis reset)
what is light pattern on IMC boards?
 
Hi
I have reseated the board and the error has gone.However i know have another error E001.I have no manual for the machine or instalation disks so working a bit blind.
I have 2 wires i cant find a home for.pleasIMG_1798.jpgIMG_1798.jpgIMG_1798.jpge see attached
 
That error message states that the machine
thinks it is in a short circuit. Those two
wires, I believe go to the ram(head)+ and
the other to the table -. Not 100% sure of this.
Is there a wire connected to the ram?

Also if you provide an email, I will send you
a PDF of the manual.
 
Thanks for your help.
There is a wire connected to the ram(red) and another connected to the table(blue).Th e manual would be handy.The machine has lay idle for a few years.Would it need instalation disks or should that be all in there?
My email is [email protected]
Kind regards
Paul
 
Hi
Could you give me an example program of how i would spark a internal spline in the x- plane.
I have looked for examples in the manual but there is nothing.
Kind regard
Paul
 








 
Back
Top