Agiecut 200d. Error 1117: Close accidenntal touching guard 2

Error appeared: 1117 Close touch protection 2. Does not allow the program to run.
Under it fall the two terminal security. The tank wire and security door spool.
Both limit switches are closed. Ring out. They come on a J8 connector, on the back wall of the machine WD 40 F (wide distribution). Where next is the signal, I do not know, need a scheme. Who will tell you where to put the jumper to get around this problem? where is the security signal summed up? Where to ring after the J8 connector? The problem is floating. There's probably no stable contact somewhere.
Help who knows,the machine stood up.
 

Attachments

  • 1111.jpg
    1111.jpg
    94.3 KB · Views: 95
Last edited:
Hi Serg, check for 24VDC on the backboard of the CD cabinet find slot P19 plug J2 pin 27C. this is board STB-01. output of board is 5VDC on J1 pin 4C open and close doors 24VDC should go high-low same for 5VDC. if 5VDC does not change it is STB-01. Swap with STB-01 in slot P20 to confirm.
If 5VDC changes state swap DBE-01s in slots P11 and P12. if problem goes away it is DBE-01. let me know what is needed.
 








 