Alarm Problems with Mitsubishi Wire EDM
Close
Login to Your Account
Results 1 to 20 of 20
  1. #1
    Join Date
    May 2014
    Location
    San Dimas, California
    Posts
    19
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default Alarm Problems with Mitsubishi Wire EDM

    Hey guys,
    I'm having some problems with my Mitsubishi wire EDM machine, the power went out and when I re-booted the machine a few alarms came up after the OS finished starting up.

    Here are the problems:
    1. S01 Servo Alarm
    2. PR 0025 X Please Ref. Return XY

    I know that doing an origin return would clear problem #2, unfortunately the machine cannot be put into "ready" mode in order to perform the origin return. As for the servo alarm, I am clueless on how to fix it. Any help would be greatly appreciated.

    Some side Notes:
    - I already tried shutting the machine down and restarting it (silly I know but sometimes it works) with no luck, and I have navigated through the menus with no luck.
    - The machine is around 8-10 years old

  2. #2
    Join Date
    Feb 2010
    Location
    Emmett Michigan U.S.A.
    Posts
    66
    Post Thanks / Like
    Likes (Given)
    35
    Likes (Received)
    35

    Default

    I had a servo alarm after a thundstorm, and had to reload the software, thats on an fx-10 also your battery might be dead.

    Bruce

  3. #3
    Join Date
    May 2014
    Location
    San Dimas, California
    Posts
    19
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Quote Originally Posted by bruce h View Post
    I had a servo alarm after a thundstorm, and had to reload the software, thats on an fx-10 also your battery might be dead.

    Bruce
    Is there a specific way I can check the battery to see if it is shot (sorry I'm relatively new and don't know much). I can try reloading the software, any idea on how long that took?

  4. #4
    Join Date
    Jan 2011
    Location
    Indiana USA
    Posts
    100
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    42

    Default

    Check the lights on the actual servo drives. I am not familiar with Mits EDM stuff but you may have blown one with the sudden power loss which may very well not have been just a loss of power but also a surge.

  5. #5
    Join Date
    Nov 2011
    Location
    CANADA
    Posts
    609
    Post Thanks / Like
    Likes (Given)
    40
    Likes (Received)
    185

    Default

    I have had both batteries go bad (Large one on control floor and the NiCad on the board) Neither caused a servo alarm.

    I would direct your attention to the servo boards as ConstantWave said. I would try unhooking the wire harness from each one before power-up. Try any trouble-shoot which one is the problem. I do not have an FX wire, but an EX sinker of the same era.

  6. #6
    Join Date
    May 2014
    Location
    San Dimas, California
    Posts
    19
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Quote Originally Posted by ConstantWave View Post
    Check the lights on the actual servo drives. I am not familiar with Mits EDM stuff but you may have blown one with the sudden power loss which may very well not have been just a loss of power but also a surge.
    I shut the whole machine down, powered it all down to check those lights, nothing was on/out of the norm. When I turned it back on the servo alarm went away. Thanks for the helpful advice guys, its very much appreciated.

  7. #7
    Join Date
    Feb 2006
    Country
    UNITED STATES
    State/Province
    New Jersey
    Posts
    1,420
    Post Thanks / Like
    Likes (Given)
    7
    Likes (Received)
    49

    Default

    What model machine, and what is the exact alarm? There should be numbers after the "S01" along with an axis designation, like "S01 Servo Alarm 0056 X" or such.

    You need to turn the breaker off for about 10 seconds then back on to clear an S01/S03 servo alarm. That alarm is generated by the servo amp and only removing power to the amp (breaker off) clears it.

  8. Likes Space Wolf, tvalen1432, roysol liked this post
  9. #8
    Join Date
    Feb 2010
    Location
    Emmett Michigan U.S.A.
    Posts
    66
    Post Thanks / Like
    Likes (Given)
    35
    Likes (Received)
    35

    Default

    Thanks MitsTech thats good to know

    Bruce

  10. #9
    Join Date
    Oct 2017
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    31
    Post Thanks / Like
    Likes (Given)
    3
    Likes (Received)
    3

    Default

    Same issue on a fa10, was this ever fixed?

  11. #10
    Join Date
    Oct 2017
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    31
    Post Thanks / Like
    Likes (Given)
    3
    Likes (Received)
    3

    Default

    Quote Originally Posted by jm0502 View Post
    Same issue on a fa10, was this ever fixed?
    Battery in the xy board was bad.

  12. #11
    Join Date
    Nov 2014
    Country
    UNITED STATES
    State/Province
    California
    Posts
    28
    Post Thanks / Like
    Likes (Given)
    65
    Likes (Received)
    2

    Default

    Mits Tech: Could you check out my thread if you have time? I have a Mits FX10 and there is a few issues going on but I am thinking they are due to either the resin pump going out or the circulation pump(?) going out. It keeps giving me either dirty side low or clean side low and neither are low at the time of alarm. I could really use the guidance.