What's new
What's new

Help with Agie Charmilles SE1 EDM!!

edmgav

Plastic
Joined
Dec 18, 2013
Location
Australia
ImageUploadedByTapatalk1406016267.119629.jpgHi. I have a cnc edm. It was working fine 2 weeks ago when I used it. But I booted it up today at it came up with the error E044 "synchronisation error with generator" and I can't clear the alarm to home the machine or use it. The machine is a 2007 SE50 CNC EDM. Any help would be great!!
 
I am not familiar with your particular model, but if this error refers to syncing two computers inside your edm, you may need to boot BOTH computers. On the charmille I had, there is a circuit breaker inside the electrical cabinet that must be opened for 10 seconds or so, then closed to re-boot the machine computer. This may not work at all with your model, or may not even be related to your problem.
 
Thanks @agieman. Step 2 was my issue SDC-12 wasn't seated correctly.
You seem to have a more extensive explanation in that alarm manual? Any chance I could get my hands on it? Thanks again. [email protected]
 
Hi!
help me.
Agie Charmilles ACTSPARK SP1
Eror E051
Z-AXIS ERROR, RESET AFTER CHECK

maybe you have a table of fault codes, schemes?
where to look?
 








 
Back