A T215 sequence alarm is exactly what it says, something went wrong which interrupted the sequence expected. If you go to the maintenance screen and then the alarm screen, and look at the section called alarm memo, it will show a "U" alarm, (clean side low etc), this is what caused the sequence to be interrupted, fix this and hey presto no more T215.