    Guys,

    Take a look at the attached picture of my Di water set up on my wire EDM machine. To summarize;
    -the city water enters the system via the copper pipe on the right
    -there is a filter to catch any sediment that may be present, there is a pressure gauge prior to the sediment filter
    -after it exits the sediment filter, the water flows into the first tank via Tygon hose which is equipped with a sight gauge/strainer.
    -exits the second tank, and continues to the machine.
    The issue being, that when the machine is in need of water, I like to fill it thru the Di tanks, but they seem to not have adequate flow thru them...as if they are clogged. So I get impatient, and fill the machine; that sends the resistivity crashing, thus the machine acts goofy until it reaches its happy place.

    Would I be better off running the tanks in parallel versus in a series as such as the current set up (I just thought of this as I was typing)? Does anyone else have these issues?

    Thanks for the input,
    Mark
    Attached Thumbnails Attached Thumbnails di-system.jpg  

  2. #2
    Join Date
    May 2011
    Country
    UNITED STATES
    State/Province
    New Jersey
    Posts
    3,002
    Post Thanks / Like
    Likes (Given)
    301
    Likes (Received)
    1654

    Default

    I usually just fill off the bottle on the machine.

  3. #3
    Join Date
    Jun 2013
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    35
    Post Thanks / Like
    Likes (Given)
    18
    Likes (Received)
    10

    Default

    My $.02?

    Top off your tank(s) every morning. That way it never takes too long.

    Dan

  4. Likes mymachinery liked this post
  5. #4
    Join Date
    May 2021
    Country
    UNITED STATES
    State/Province
    Pennsylvania
    Posts
    6
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    2

    Default

    Quote Originally Posted by M. Roberts View Post
    Guys,

    Take a look at the attached picture of my Di water set up on my wire EDM machine. To summarize;
    -the city water enters the system via the copper pipe on the right
    -there is a filter to catch any sediment that may be present, there is a pressure gauge prior to the sediment filter
    -after it exits the sediment filter, the water flows into the first tank via Tygon hose which is equipped with a sight gauge/strainer.
    -exits the second tank, and continues to the machine.
    The issue being, that when the machine is in need of water, I like to fill it thru the Di tanks, but they seem to not have adequate flow thru them...as if they are clogged. So I get impatient, and fill the machine; that sends the resistivity crashing, thus the machine acts goofy until it reaches its happy place.

    Would I be better off running the tanks in parallel versus in a series as such as the current set up (I just thought of this as I was typing)? Does anyone else have these issues?

    Thanks for the input,
    Mark
    I have an extra bottle on a water line I only use for filling the tank.