miller 180sd post flow to long
I have a 180sd and the pre and post flow factory set at 18 seconds but mine is running 35 seconds is there an easy way to make the flow adjustable Thanks Ken
-
-
10-15-2019, 11:28 AM #2
There is a menu that you get into that allows you to set the timers and other parameters. This is in the manual.
-
10-15-2019, 11:45 AM #3
Older machine not adjustable Ken
-
10-15-2019, 12:23 PM #4
https://www.google.com/url?sa=t&rct=...7eE5_mwr6RBRGw
Here is a link to the manual for your machine. Instructions are on page 16 for post flow timer.
-
10-15-2019, 03:37 PM #5
Zeggy i got my manual out it tells me that pre & postflow are preset and can't be reset ken
-
-
10-15-2019, 03:44 PM #6
What’s the amperage set to? Some machines auto adjust the post flow for high amp work. I don’t know if that machine had it or not.
-
10-15-2019, 07:18 PM #7
In manual its .3 preflow and 18 postflow but the postflow is 35seconds lots of lost argon lost ken
-
10-15-2019, 08:15 PM #8
you might have a hardware problem. If your machine is fixed and it is supposed to be at 18secs and yet your post flow is 35secs, that sounds like a bad timer.
How is the timer shown in your schematic? A discrete device or part of a blackbox that is nondescript.
I have never seen a 180SD that did not have the postflow menu. Learned something new.