Air Compressor Pressure switch, mag starter wiring problems

Fred T

Cast Iron
Joined
Jan 20, 2003
Location
Ohio
Gentlemen,
Does anyone have a photo they could share of a correctly wired Square D mag starter using a pressure switch as an off and on for an air compressor. The coil is 208-220v, as is the 5 hp motor. The mag starter/overload is new as is the pressure switch. I don't read schematics very well at all thus the photo request.

Thank you all
Fred T
 
whats the picture of what you currently have and what does the diagram say?

essentially you have your power feed line in at one side of the large lugs, output on the other and a switch that turns on the magnet coil on top
 
BT,
The mag starter came without any wiring diagram, that may be a large part of my problem.
 
Not a square D but an Eaton on my new Champion, maybe that helps
 

Attachments

  • D36DC02B-4F79-4A80-BD0C-D6427C81832B.jpg
    D36DC02B-4F79-4A80-BD0C-D6427C81832B.jpg
    20.2 KB · Views: 73
  • 88D6C629-2713-4D51-9A07-9865BCEA216C.jpg
    88D6C629-2713-4D51-9A07-9865BCEA216C.jpg
    16.7 KB · Views: 67
  • ADB9AA1A-73A4-43D3-A802-6A553A82254D.jpg
    ADB9AA1A-73A4-43D3-A802-6A553A82254D.jpg
    19.3 KB · Views: 41
  • 17FE1628-4BDF-4293-B63B-51E82CB8A7EA.jpg
    17FE1628-4BDF-4293-B63B-51E82CB8A7EA.jpg
    17.6 KB · Views: 38
put your pressure switch contact terminals in series with your coil leads. Your on- off switch should also be in series in the same circuit. The contactor does not need to latch if you are turning on and off via the pressure switch, so you don't need to use any aux contact terminals on the motor starter.
 
Doesn't that negate the mag starter?

Gentlemen,
All is good in the world, I had an electrician stop over and take care of it. it did help that Schneider Electronics sent me a schematic and my friend know what he was looking at. Thank you all for taking the time to look and try to help.

Fred T
 








 