300 psi TSC pump surging when using small drills.
Close
Login to Your Account
Results 1 to 13 of 13
  1. #1
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default 300 psi TSC pump surging when using small drills.

    I noticed it today when we were using a 5.9 mm drill.
    Tool is an OSG Mega Muscle with really small coolant holes, probably .02-.03" dia.
    It surges up and down and the coolant flow is changing constantly.
    The pump does fine with other tools that have larger coolant holes.

    Anything to do about it? Or is it just normal?

  2. #2
    Join Date
    Dec 2003
    Location
    poulsbo, wa, usa
    Posts
    1,031
    Post Thanks / Like
    Likes (Given)
    72
    Likes (Received)
    441

    Default

    I have a feeling your pump is cavitating do to the little amount of flow its seeing ,,, you might try a dump valve so you can increase the flow going throe the pump ,,, I have had lathe pumps do that when there is only one small jet to flow coolant … I just put in a dump valve and would dump some coolant from the pump back into the sump to fix it ..

  3. #3
    Join Date
    Aug 2014
    Location
    bainbridge island
    Posts
    1,257
    Post Thanks / Like
    Likes (Given)
    261
    Likes (Received)
    297

    Default

    cavitation is also influenced by the gas pulled out of the fluid on the suction side of the pump. if the gas does not get pushed downstream it flows around the impeller through the seals. or lack of seals, and the pumping action nearly stops.

    check inlet filter restrictions.

  4. #4
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default

    I was wondering about that, because it sounded like it was cavitating a bit.
    So it's more or less bypassing internally?

  5. #5
    Join Date
    Nov 2014
    Country
    UNITED STATES
    State/Province
    Florida
    Posts
    4,549
    Post Thanks / Like
    Likes (Given)
    1745
    Likes (Received)
    2180

    Default

    I don't know this for fact, but I was taught that 300psi isn't enough for smaller tools... don't know the reasoning behind that?

  6. #6
    Join Date
    Jul 2007
    Country
    UNITED KINGDOM
    Posts
    5,032
    Post Thanks / Like
    Likes (Given)
    2860
    Likes (Received)
    2474

    Default

    If it's a centrifugal pump, it is either stalling with the low flow or the coolant is recirculating in the pump. A dump valve will help cure either case. Cavitation in a centrifugal pump occurs when the inlet is restricted and the net positive suction head gets below the vapour pressure of the fluid.

  7. #7
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default

    Would the dump valve be activated via an M-code?
    And how would you control the flow being relieved, IOW so it doesn't all go through the dump valve?

  8. #8
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default

    Quote Originally Posted by Mike1974 View Post
    I don't know this for fact, but I was taught that 300psi isn't enough for smaller tools... don't know the reasoning behind that?
    Theory is that you need more pressure to force coolant through the small holes.
    All too true......

  9. #9
    Join Date
    Feb 2004
    Location
    Staten Island NewYork USA
    Posts
    3,851
    Post Thanks / Like
    Likes (Given)
    1148
    Likes (Received)
    1892

    Default

    T the line it with a manually adjustable valve. Turn coolant on and open valve till your pumps working correctly and run it that way for all your tools. When done with job, shut the valve. OR buy an electric valve to go more elaborate that opens and shuts the T- feed to the manual...you still need to control the flow.

  10. Likes ChipSplitter liked this post
  11. #10
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default

    Quote Originally Posted by SIM View Post
    T the line it with a manually adjustable valve. Turn coolant on and open valve till your pumps working correctly and run it that way for all your tools. When done with job, shut the valve. OR buy an electric valve to go more elaborate that opens and shuts the T- feed to the manual...you still need to control the flow.
    I could probably put a solenoid valve and a flow control together and control it that way.....

  12. #11
    Join Date
    May 2017
    Country
    UNITED STATES
    State/Province
    Minnesota
    Posts
    1,221
    Post Thanks / Like
    Likes (Given)
    1534
    Likes (Received)
    824

    Default

    I believe there's an overpressure relief valve, that could be toggling. I have 1000PSI TSC, and when a small drill is in the work I'll hear a rhythmic thumping sound as it oscillates. Don't hear it if there's reasonable flow or if it's fully blocked with a non-TSC holder.

  13. #12
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default

    Quote Originally Posted by mhajicek View Post
    I believe there's an overpressure relief valve, that could be toggling. I have 1000PSI TSC, and when a small drill is in the work I'll hear a rhythmic thumping sound as it oscillates. Don't hear it if there's reasonable flow or if it's fully blocked with a non-TSC holder.
    Yes, that's what it sounds like. I'll put a dump valve in the next time we use that tool (2-6 weeks) and let you guys know if it worked.

  14. #13
    Join Date
    May 2019
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    1,540
    Post Thanks / Like
    Likes (Given)
    446
    Likes (Received)
    738

    Default Update:

    We had a job this morning that used that same drill so I teed in a needle valve. The pump now sounds a lot better and doesn't cavitate.

    Thanks for all your help guys.