H&T agreement + probing
I want to turn H&T code agreement off to use the whole tool table on my CM-1, but does that break tool probing? The parameters for P9023/P9853 seem to only have the Tool number, not a length or diameter offset into the table, so both measuring and break detection wouldn't work? I am not opposed to writing new macros, just hoping I am missing something and they aren't needed.
-
-
01-14-2021, 08:14 AM #2
I have H&T code agreement turned off with no effect on measuring tools.
On mine, tool breakage won't work with it turned on.
-
01-14-2021, 01:30 PM #3
-
01-14-2021, 03:49 PM #4
-
01-15-2021, 07:07 PM #5
But that only has the T number, how would you tell it to update H175 instead of H1?
-
-
01-16-2021, 09:40 AM #6
I suppose you could read and reassign the system variable for H1. You can also use G10 to set length, dia, etc. I don’t think there is a way to strictly use the probing routine though.