Hello,

I have haas cnc machine vf1 from 1998. and on machine I have very strange behaviour. When I startup machine and press reset up button I got door open alarm. I have tried everything from short connecting digital input on pcb (jumper on 1050) to disabling parameter 51 door override. Also I tried to simulate opening and closing door on digital input and switching off parameter 7 (unlocking parameters) but no luck. Machine is in Europe and I have read on forums that for this market something is different but I am not sure what? It is very strange why it is not working when I bypass digital input of door switch?
Thank you for your help,
Regards.
 
I have to do this on my lathe, but it does work(I'm going to double check, I'm thinking parameter 41).

Anyway, have to do the same thing on the Haas Router.... only there is no door.
 
No it is parameter 51. When I change it there is not warning message to confirm with Y but online I found that everyone get that warning message when they change parameter 51.
 








 