HELP!
Recently bought a used 1998 Haas VF-OE 20hp. Got it in place and wired up. Have balanced load with input voltages matching input terminals (highest position). Spindle sounds good when running.
Trying to run the 'spindle warm up' program below but keep getting error 107 EMERGENCY OFF when it switches to some speeds above 2000. Have been able to run up to 2000 and manually increase using 'spindle speed override'. Also the problem is NOT consistent. Appears to sometimes error out at 2400ish and sometimes anything above 4000. But never able to fully execute the below program.
Have also played with the program to start at 1000 then ramp up every 1000 or 1500 rpm after 10 seconds or so to try and isolate the problem. I've tried various speeds and have gotten various results. Sometimes spindle load bounces to 100%+ when changing a speed and sometimes it would barely register. After getting the 107 code and then checking the cabinet there is nothing to indicate fault or error other than RED BEACON led on IO board. Spindle drive shows no fault.
Dont see any loose connections or burned fuses. E-Stop button has freshly cleaned contacts and the 107 error is 'reset-able'. I tried it either way, with the counter-balance sensor jumpered, or connected and had same results.
What in the machine would throw that particular error code 107 EMERGENCY STOP besides pressing E-stop button or counterbalance error?
All other errors such as air, oil, drives, power, tool changer etc have their own error code designators. Right?
I've seen NOTHING online anywhere about this problem.
Dying here.
%
O02020 (Spindle Warm-up)
(This program should be run prior to)
(machine use if machine has been idle)
(for more than 4 days.)
(Cycle time: 20-minutes.)
(This program can be used for all)
(spindle types and may be used daily)
(for spindle warm-up prior to high)
(speed spindle use. Adjust spindle)
(speed override depending on maximum)
(spindle speed of machine: Set)
(override at 50% for 5,000 rpm)
(machines, set at 100% for 7,500)
(& 10,000 rpm machines, and set at)
(150% for 15,000 rpm machines.)
(9-21-99)
S500 M03
G04 P200.
S1000 M03
G04 P200.
S2500 M03
G04 P200.
S5000 M03
G04 P200.
S7500 M03
G04 P200.
S10000 M03
G04 P200.
M30
%
Recently bought a used 1998 Haas VF-OE 20hp. Got it in place and wired up. Have balanced load with input voltages matching input terminals (highest position). Spindle sounds good when running.
Trying to run the 'spindle warm up' program below but keep getting error 107 EMERGENCY OFF when it switches to some speeds above 2000. Have been able to run up to 2000 and manually increase using 'spindle speed override'. Also the problem is NOT consistent. Appears to sometimes error out at 2400ish and sometimes anything above 4000. But never able to fully execute the below program.
Have also played with the program to start at 1000 then ramp up every 1000 or 1500 rpm after 10 seconds or so to try and isolate the problem. I've tried various speeds and have gotten various results. Sometimes spindle load bounces to 100%+ when changing a speed and sometimes it would barely register. After getting the 107 code and then checking the cabinet there is nothing to indicate fault or error other than RED BEACON led on IO board. Spindle drive shows no fault.
Dont see any loose connections or burned fuses. E-Stop button has freshly cleaned contacts and the 107 error is 'reset-able'. I tried it either way, with the counter-balance sensor jumpered, or connected and had same results.
What in the machine would throw that particular error code 107 EMERGENCY STOP besides pressing E-stop button or counterbalance error?
All other errors such as air, oil, drives, power, tool changer etc have their own error code designators. Right?
I've seen NOTHING online anywhere about this problem.
Dying here.
%
O02020 (Spindle Warm-up)
(This program should be run prior to)
(machine use if machine has been idle)
(for more than 4 days.)
(Cycle time: 20-minutes.)
(This program can be used for all)
(spindle types and may be used daily)
(for spindle warm-up prior to high)
(speed spindle use. Adjust spindle)
(speed override depending on maximum)
(spindle speed of machine: Set)
(override at 50% for 5,000 rpm)
(machines, set at 100% for 7,500)
(& 10,000 rpm machines, and set at)
(150% for 15,000 rpm machines.)
(9-21-99)
S500 M03
G04 P200.
S1000 M03
G04 P200.
S2500 M03
G04 P200.
S5000 M03
G04 P200.
S7500 M03
G04 P200.
S10000 M03
G04 P200.
M30
%