On a nexgen control mill, if I want to run in metric mode, will I need to change a bunch of settings for the probe, recalibrate, re-touch-off tools, etc?

Thanks
 
On a nexgen control mill, if I want to run in metric mode, will I need to change a bunch of settings for the probe, recalibrate, re-touch-off tools, etc?

Thanks



9 - Dimensioning
This setting selects between inch and metric mode. When it is set to INCH, the programmed units for X, Y, and Z are inches, to 0.0001". When it is set to MM, programmed units are millimeters, to 0.001 mm. All offset values are converted when this setting is changed from inches to metric, or vice versa. However, changing this setting does not automatically translate a program stored in memory; the programmed axis values must be changed for the new units.

When set to INCH, the default G-code is G20, when set to MM, the default G-code is G21.