Hi,
I just got a 2006 TM-1 which the previous owner had hooked up to three phase. I'm hooking it up in my garage to 240V single phase 60HZ in the USA (I measured 242VAC across the hot leads).
After reading Electrical_Service_Manual_96-0284A_Rev_A_English_June_2006.pdf pages 5-7 I have some questions...
Here is the diagram from page 5:
And here is a picture of my cabinet:
They are a bit different. In my cabinet I don't have anything that looks like the "Transformer" (lower right in diagram from page 5). I'm guessing I have "115VAC MAIN TRANSFORMER" instead?:
I think I need to do the following:
Is this correct? Do I need to do anything else?
Thanks,
Rob
I just got a 2006 TM-1 which the previous owner had hooked up to three phase. I'm hooking it up in my garage to 240V single phase 60HZ in the USA (I measured 242VAC across the hot leads).
After reading Electrical_Service_Manual_96-0284A_Rev_A_English_June_2006.pdf pages 5-7 I have some questions...
Here is the diagram from page 5:
And here is a picture of my cabinet:
They are a bit different. In my cabinet I don't have anything that looks like the "Transformer" (lower right in diagram from page 5). I'm guessing I have "115VAC MAIN TRANSFORMER" instead?:
I think I need to do the following:
- Wire 120V hot leads to L1 and L3, connect ground lead
- Change jumper on "115VAC MAIN TRANSFORMER" to "PRIMARY 224-250V"
- Change jumper on "T5 24VAC" transformer to "221-240V"
Is this correct? Do I need to do anything else?
Thanks,
Rob