Freqrol fr-se on Mazak
Close
Login to Your Account
Likes Likes:  0
Results 1 to 8 of 8
  1. #1
    Join Date
    Oct 2019
    Country
    POLAND
    Posts
    23
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    3

    Default Freqrol fr-se on Mazak

    Hi,
    Again we have problem with our QT15N. Our inverter displays an error after turning on the power. It's E7 alarm. But when we turn on the main panel, it's ready to work (shows "r 0"), but it doesn't supply power to the spindle motor. Main panel shows only alarm 128 Emergency stop.

    Adds a video to clarify the situation:
    YouTube

  2. #2
    Join Date
    Apr 2013
    Location
    South Australia
    Posts
    439
    Post Thanks / Like
    Likes (Given)
    119
    Likes (Received)
    148

    Default

    Are there any LED's lit on the spindle drive?

  3. #3
    Join Date
    Feb 2015
    Country
    SWEDEN
    Posts
    605
    Post Thanks / Like
    Likes (Given)
    106
    Likes (Received)
    291

    Default

    If you check under diagnos screen, is there any other alarm then 128?
    You should have 204 if there is a problem with spindle drive.

    (I think you have a FR-SF drive and not a FR-SE)

  4. #4
    Join Date
    Feb 2015
    Country
    SWEDEN
    Posts
    605
    Post Thanks / Like
    Likes (Given)
    106
    Likes (Received)
    291

    Default

    I dont have the manual in front of me but I think E7 is normal when starting up the machine (machine not ready or something like that)

    Is it a T32?

  5. #5
    Join Date
    Oct 2019
    Country
    POLAND
    Posts
    23
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    3

    Default

    Yes you are right, its FR-SF. Its T32-2 and there is only one alarm on diagnos. E7 is NC Emergency. I will check these leds as soon as I can.

  6. #6
    Join Date
    Oct 2019
    Country
    POLAND
    Posts
    23
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    3

    Default

    So, there are 2 LEDs on the power supply SF-PW.
    Led 1 (green) and led 2 (orange)

    On the SF-CA card there are just Led 2 (orange), When the main panel is switched on, the LED 10 (orange) lights up and after a while turns off.

    Also I saw there is 56 alarm on my servo drive, look at the video:
    YouTube

  7. #7
    Join Date
    Oct 2019
    Country
    POLAND
    Posts
    23
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    3

    Default

    Manual says that:
    LED2 on SF-CA card - Lights when the base of the inverter/converter transistor
    cuts off.

    Any ideas?

  8. #8
    Join Date
    Oct 2019
    Country
    POLAND
    Posts
    23
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    3

    Default

    It looks like the inverter has lost parametrs. You know where I can get them or someone will share theirs with me? Inverter is FR-SF-2-18.5KP-BCK and the motor is SJ-18.5BW4