    Hello.
    There are several problems, in this thread there are questions and solutions.
    Everything in order
    Problem number 1:
    Mazak QT-6T Mazatrol T + (plus) machine worked with a barfeeder.
    Now I turned on the machine without a bar feeder and an error appeared on the display: 33 EMERGENCY STOP.
    It is not possible to reset the error, the machine does not respond.
    The EMERGENCY STOP button and limit switches are working properly.
    Maybe you need to fix something in the PLC?
    please any help ...
    1.jpg
    2.jpg
    3.jpg
    4.jpg

  2. #2
    Join Date
    Jun 2013
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    1,782
    Post Thanks / Like
    Likes (Given)
    644
    Likes (Received)
    1099

    Default

    You may have more than one alarm. Look at you "DIAGNOSE" page. This will show if you have more than one alarm.

  3. #3
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Quote Originally Posted by Gobo View Post
    You may have more than one alarm. Look at you "DIAGNOSE" page. This will show if you have more than one alarm.
    Only 33 EMERGENCY STOP.
    5.jpg
    What do these readings mean? (operating time):
    Power ON -
    Auto CUT -
    Auto OPR -
    Total CUT -

  4. #4
    Join Date
    May 2009
    Location
    The Woodlands, Tx
    Posts
    602
    Post Thanks / Like
    Likes (Given)
    77
    Likes (Received)
    91

    Default

    it is the missing estop button that was on the bar feeder. did you change parameters to tell machine to not look for the bar feeder? you may need to add jumper on board where the missing estop plugged in

    Justin

  5. #5
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Quote Originally Posted by Justin_Terry View Post
    it is the missing estop button that was on the bar feeder. did you change parameters to tell machine to not look for the bar feeder? you may need to add jumper on board where the missing estop plugged in
    Justin
    I'm new to Mazak.
    I don’t know where to change the settings so the machine doesn’t look for the bar feeder.
    That's why I'm here to help me)

  6. #6
    Join Date
    Jun 2013
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    1,782
    Post Thanks / Like
    Likes (Given)
    644
    Likes (Received)
    1099

    Default

    Do you have any machine manuals for it?

  7. #7
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Quote Originally Posted by Gobo View Post
    Do you have any machine manuals for it?
    I have only:
    - parameter list
    - operating manual.

    I need for Mazatrol T plus
    - electrical circuit
    - how to disable polling of the bar feeder from the PLC?

    I want to remove the extra wires, relays and starters that were used for the bar feeder.
    But first, I need to start the machine.
    Any help is appreciated.

  8. #8
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    I look forward to your help.)

    problem number 2:
    Why is there only Mazatrol when creating a new program?
    the option specifies EIA/ISO
    img_20210419_193511.jpgimg_20210419_193537.jpg
    does it need to be activated in the parameters?
    sorry i'm new to mazak
    Last edited by gerka; 04-21-2021 at 06:17 AM.

  9. #9
    Join Date
    May 2009
    Location
    The Woodlands, Tx
    Posts
    602
    Post Thanks / Like
    Likes (Given)
    77
    Likes (Received)
    91

    Default

    you have none of those options. and you dont need to remove anything off of machine to disable bar feeder, just change parameters and possibly add a jumper to complete e stop circuit.

  10. #10
    Join Date
    Jun 2013
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    1,782
    Post Thanks / Like
    Likes (Given)
    644
    Likes (Received)
    1099

    Default

    Quote Originally Posted by Justin_Terry View Post
    you have none of those options. and you dont need to remove anything off of machine to disable bar feeder, just change parameters and possibly add a jumper to complete e stop circuit.
    correct. If the option is highlighted, it is active.

  11. #11
    Join Date
    Jun 2013
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    1,782
    Post Thanks / Like
    Likes (Given)
    644
    Likes (Received)
    1099

    Default

    Quote Originally Posted by gerka View Post
    I have only:
    - parameter list
    - operating manual.

    I need for Mazatrol T plus
    - electrical circuit
    - how to disable polling of the bar feeder from the PLC?

    I want to remove the extra wires, relays and starters that were used for the bar feeder.
    But first, I need to start the machine.
    Any help is appreciated.
    I am pretty sure that a parameter change is needed to disable the barfeeder. Have you looked through the parameter list ?

  12. #12
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    thank you for your help. I rang the bar feeder connector pins and found where to put the jumper for error 33.
    now there are other alarms that I am solving.

    help me activate EIA / ISO

  13. #13
    Join Date
    Nov 2012
    Country
    UNITED STATES
    State/Province
    Wisconsin
    Posts
    110
    Post Thanks / Like
    Likes (Given)
    284
    Likes (Received)
    14

    Default

    Quote Originally Posted by gerka View Post
    I'm new to Mazak.
    I don’t know where to change the settings so the machine doesn’t look for the bar feeder.
    That's why I'm here to help me)
    press the "machine" button.
    then "option" soft key.
    make sure "barfeed" is not highlighted.

  14. #14
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Thanks for your answers and help.
    I solved an error 33, jumper, but I had other errors.
    img_20210422_131610.jpg
    Now in search of their decision.

    What do you think I can't write a new program in EIA / ISO (G-Code)
    Any ideas?

  15. #15
    Join Date
    May 2009
    Location
    The Woodlands, Tx
    Posts
    602
    Post Thanks / Like
    Likes (Given)
    77
    Likes (Received)
    91

    Default

    no eia without the option you will have to call mazak and buy the option.

    look for parameter that sets if the chuck is looking for confirmation sensors or just on timer. it is currently set to sensors, that is why you are getting alarms.

  16. #16
    Join Date
    Apr 2021
    Country
    SLOVENIA
    Posts
    8
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Quote Originally Posted by Justin_Terry View Post
    no eia without the option you will have to call mazak and buy the option.
    are you sure the EIA / ISO is not?
    in the list of options number 2.

  17. #17
    Join Date
    May 2009
    Location
    The Woodlands, Tx
    Posts
    602
    Post Thanks / Like
    Likes (Given)
    77
    Likes (Received)
    91

    Default

    100% the option page you posted does not have eia.

  18. #18
    Join Date
    Jun 2013
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    1,782
    Post Thanks / Like
    Likes (Given)
    644
    Likes (Received)
    1099

    Default

    Quote Originally Posted by Justin_Terry View Post
    100% the option page you posted does not have eia.
    Yes for sure, No EIA


Tags for this Thread