SQT-10M Spindle Start-up
Close
Login to Your Account
Likes Likes:  0
Results 1 to 3 of 3
  1. #1
    Join Date
    Nov 2015
    Country
    UNITED STATES
    State/Province
    Washington
    Posts
    88
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    6

    Default SQT-10M Spindle Start-up

    SQT-10M T-Plus
    Can anyone tell me which parameter I need to change for the spindle accel time.
    I need to reduce the startup load a little. Mazak wasn't quite sure and Mitsubishi told me SP19 but he didn't sound really confident about that. So I was hoping someone could verify the right parameter to change. Mine right now is set to 30.
    Thanks!

  2. #2
    Join Date
    Feb 2010
    Location
    South Jersey
    Posts
    38
    Post Thanks / Like
    Likes (Given)
    4
    Likes (Received)
    5

    Default

    On my SQT-18MS T32-3, SP19 is the correct parameter.
    My factory setting was 300, it is now set to 500.
    Hope that helps!

  3. #3
    Join Date
    Nov 2015
    Country
    UNITED STATES
    State/Province
    Washington
    Posts
    88
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    6

    Default

    I finally found someone at Mitsubishi that knew for sure it was SP19. The T32-3 might be a bit different than the T-Plus because mine was set at 30 and they said that was factory. But after trying different settings I ended up at 250 which I'll see how that works out. Thanks for confirming that was the right parameter.