Any Faro Cam2 gurus here?

I am working on cmm data using faro arm/cam2. I have a composite feature control frame the second call out is position of holes ".013|MMC|A". I realize this is referencing the holes location relative to each other and the pattern they form. I can not get the software to compute this properly. The deviation is either the same as my ABC locations or is reading .000. The .000 reading, I think this is the software computing perpendicularly to datum A(surface plate)not position. Can anyone help me? Is the CAM2 software capable of computing this callout?
 








 