Help with DRO
Close
Login to Your Account
Likes Likes:  0
Results 1 to 4 of 4

Thread: Help with DRO

  1. #1
    Join Date
    Jan 2004
    Location
    Chicago, IL
    Posts
    195
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    8

    Default Help with DRO

    img_0344-3-.jpg

    I have this BATY DRO on an optical comparator.
    The DRO is displaying exactly half of the actual size of the object I'm measuring.
    It displays half in both X and Y axis.
    I don't have a manual for this and I can't figure out if there is a way to
    re-calibrate. Any ideas.
    Thanks

  2. #2
    Join Date
    Dec 2018
    Country
    UNITED STATES
    State/Province
    Arizona
    Posts
    55
    Post Thanks / Like
    Likes (Given)
    7
    Likes (Received)
    38

    Default

    We have a quadra check 2000 which looks exactly the same. Try setup > super > password 070583 > prescale > 2

    We had the same issue, but just on the x axis. If the password doesn't work hopefully its on the box somewhere.

    Sent from my SM-N960U using Tapatalk

  3. #3
    Join Date
    Jan 2004
    Location
    Chicago, IL
    Posts
    195
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    8

    Default

    That was it.
    Thank you very much for the help!

  4. #4
    Join Date
    Dec 2018
    Country
    UNITED STATES
    State/Province
    Arizona
    Posts
    55
    Post Thanks / Like
    Likes (Given)
    7
    Likes (Received)
    38

    Default

    Glad it worked!

    Sent from my SM-N960U using Tapatalk


Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •