Quality Josh
Aluminum
- Joined
- Feb 4, 2015
- Location
- Calgary
I have few measuring tools that i are giving me trouble as far as calibration and them being too far out of spec from the manufactures stated accuracy, most notably inside mics, depth mics and OD anvil mics. I want to know how to handle the red sticker situation without getting dinged by the auditor. All 3 of these tools I've have tried to adjust myself but the are really difficult to get into the acceptable accuracy tolerance for the tool. I have been told by one of the engineers at my company that generally speaking when you have a tool with interchangable anvils the only way to adjust them properly is to send them back to the manufacture and get them calibrated (hard time believing this as they give you the tools to adjust in the box). The problem being is that since the oilfield slowdown they are running a really tight ship as far as spending goes. So getting back to the original question, is there a way to give them a red sticker even if they are significantly out?