Morning:
Will be helping a friend by building him a RPC. The Machine looks to still be 440v 3 phase with original motor. Has a nice magnetic starter with a buck transformer 220v to 440 volts. Can barely read motor tag but looks like 3 or maybe 5 horse???. Where there are only 2 connections on the transformer how does one connect 3 legs?

Monarch
12" CK
17.5"
30"
17615
MVTI
11-1942 date
Serial Number CK17615
Bob
 
there are only 2 connections on the transformer

Transformer is a control transformer for coil in magnetic starter.

Good chance the motor is dual voltage 220/440

Look in terminal box attached to motor and see if there are nine wires coming from motor.